Insulation contractors
Bid more thermal and acoustic packages with areas already split by product and R-value.
- Areas by product & R-value
- Bag and bundle counts
For insulation contractors
Batt, blown, rigid board and spray foam measured by assembly and R-value, so your insulation bid covers every wall, roof and slab edge on the drawings.
Multi-family building, 4 stories
Illustrative example
Every assembly in the building envelope and interior partitions, measured from sections and details.
Exterior and interior wall batts by stud depth and R-value, with openings deducted.
Blown and batt attic insulation, plus rigid roof insulation by thickness and taper.
Continuous insulation, foundation walls and slab edges by board type and thickness.
Open- and closed-cell spray foam by area and depth, converted to board feet.
Acoustic insulation in partitions and floor-ceiling assemblies.
Building wrap, fluid-applied barriers and vapor retarders by area.
Perimeter safing, curtain wall firestop and penetration counts where in scope.
Mechanical insulation by pipe size or duct area when included.
Rim joist and crawlspace insulation, often missed on the first pass.
Color-coded plan markups paired with an unlocked takeoff sheet you can load straight into your bid.
Exterior walls: R-21
48,600 SF net
Attic: R-38 blown
22,400 SF
Slab edge: 2" XPS
1,860 LF × 2' deep
Rim joists: spray foam
1,240 LF
Every measurement is color-coded and tied to its sheet number.
| Item | CSI | Net | Unit | Waste | Gross |
|---|---|---|---|---|---|
| R-21 fiberglass batts, 2×6 walls | 07 21 16 | 48,600 | SF | 5% | 51,030 |
| R-38 blown cellulose, attic | 07 21 26 | 22,400 | SF | 5% | 23,520 |
| 2" XPS rigid board, slab edge | 07 21 13 | 3,720 | SF | 8% | 4,018 |
| Closed-cell spray foam, rim joists | 07 21 19 | 6,200 | BF | 10% | 6,820 |
| R-11 sound batts, partitions | 07 21 16 | 31,800 | SF | 5% | 33,390 |
| Weather-resistive barrier | 07 25 00 | 52,400 | SF | 10% | 57,640 |
Live formulas: change any waste factor and the gross quantity updates.
Illustrative example. Areas are tied to the assembly that calls for them, then converted into bags, bundles and boards.
Each product is priced on its own, so a change in one assembly doesn't throw off the whole bid.
Cost group 01
Batts, loose fill, board and foam priced by R-value and coverage from suppliers near the job.
Local supplier pricing
Cost group 02
Install hours by assembly, height and access, from open walls to tight attics.
SF per crew-day
Cost group 03
Blowing machines, spray rigs, lifts and protection for the work.
Rigs & access
Cost group 04
Inspections, cleanup, disposal and the markup you set.
Your markup & contingency
Organized for installers, GCs and distributors.
Bid more thermal and acoustic packages with areas already split by product and R-value.
Confirm the insulation and air barrier scope is complete before you award.
Product lists by type, thickness and coverage for quick quoting.
Walls, roofs, floors, slab edges and rim joists are measured from sections and details.
Areas follow the assembly that calls for them instead of being averaged across the building.
Areas are converted into bags, bundles and boards based on coverage.
Addenda that change R-values are flagged and updated.
We note where firestopping, air barrier or mechanical insulation sits with another trade.
“An addendum dropped two days before the bid and they turned the update around the next morning. The Excel files have live formulas, so we adjust margins ourselves.”
Send what you have and we'll reply with a fixed price and delivery date before any work starts.
The same detail and turnaround for every specialty trade on the job.
Yes. Areas are grouped by assembly and R-value so each product is priced correctly, with openings deducted from wall areas.
Send your drawings and get a fixed quote for a complete thermal, acoustic and air barrier takeoff.